Model code
|
AC-SMA-02D
|
AC-SMA-05D
|
AC-SMA-10D
|
AC-SMA-15D
|
AC-SMA-20D
|
AC-SMA-30D
|
AC-SMA-50D
|
Unit
|
|
Axial
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
(parallel to the device surface)
|
|
Range
|
±2
|
±5
|
±10
|
±15
|
±20
|
±30
|
±50
|
g
|
|
Bandwidth (adjustable)
|
>120
|
>120
|
>120
|
>120
|
>120
|
>120
|
>120
|
Hz
|
|
Zero-bias stability (1s, 1σ)
|
<20
|
<20
|
<50
|
<50
|
<50
|
<100
|
<200
|
μg
|
|
Monthly repeatability
|
<100
|
<100
|
<300
|
<300
|
<300
|
<300
|
<300
|
μg
|
|
Zero-bias temperature coefficient
|
<10
|
<10
|
<30
|
<30
|
<30
|
<50
|
<100
|
μg/℃
|
|
Zero-bias temperature hysteresis
|
2
|
2
|
3
|
3
|
3
|
4
|
4
|
mg
|
|
Scale nonlinearity
|
1000
|
1000
|
2000
|
2000
|
2000
|
3000
|
3000
|
ppm
|
|
Monthly repeatability
|
<100
|
<100
|
<100
|
<100
|
<100
|
<100
|
<100
|
ppm
|
|
Scaling temperature coefficient
|
<5
|
<5
|
<5
|
<10
|
<10
|
<10
|
<10
|
ppm/℃
|
|
Scale factor
|
3750000±37500
|
1500000±15000
|
700000±7000
|
500000±5000
|
350000±3500
|
250000±2500
|
150000±1500
|
LSB/g
|
|
Startup time
|
<1
|
<1
|
<1
|
<1
|
<1
|
<1
|
<1
|
s
|
|
Sampling frequency
|
25K
|
25K
|
25K
|
25K
|
25K
|
25K
|
25K
|
Hz
|
|
Impact
|
The overload-resistant model has passed the 27000g overload test by users
|
g
|
|
Vibration rectification error (6grms)
|
/
|
/
|
<0.15
|
<0.15
|
<0.15
|
<0.15
|
<0.15
|
mg/grms
|
|
Operating Temperature
|
-55~125
|
-55~125
|
-55~125
|
-55~125
|
-55~125
|
-55~125
|
-55~125
|
℃
|
|
Power supply voltage
|
5.0±0.2
|
5.0±0.2
|
5.0±0.2
|
5.0±0.2
|
5.0±0.2
|
5.0±0.2
|
5.0±0.2
|
V
|
|
Current (typical value)
|
11
|
11
|
11
|
11
|
11
|
11
|
11
|
mA
|
|
Communication interface
|
SPI
|
SPI
|
SPI
|
SPI
|
SPI
|
SPI
|
SPI
|
|
|
Output format
|
Analog/Digital
|
Analog/Digital
|
Analog/Digital
|
Analog/Digital
|
Analog/Digital
|
Analog/Digital
|
Analog/Digital
|
|
|
Notes:
-
Long-term repeatability: Accelerometers with a range of 32 ± 50g have undergone long-term repeatability testing, and test data spanning 1.5 years is available. The proportion of accelerometers with zero-bias repeatability < 0.2mg is 31%, the proportion with zero-bias repeatability < 0.5mg is 75%, the proportion with zero-bias repeatability < 1.2mg is 100%, the proportion of accelerometers with scale factor repeatability < 100ppm is 93.7%, and the proportion with scale factor repeatability < 200ppm is 100%.
-
The smaller the measurement range, the higher the accuracy. For example, products with a ±2g measurement range have the best zero-bias stability indicator of 3μg, and also exhibit better long-term repeatability.
|